System Sensor Rrs-mod: The Ultimate Guide – Full Specifications, Comparisons, Manuals, Troubleshooting, And Where To Buy

System Sensor RRS-MOD Information

the information about the System Sensor RRS-MOD:

Introduction

The System Sensor RRS-MOD is a reversing relay/synchronization module that is used to enhance the operation of 2- and 4-wire i3™ Series detectors equipped with a sounder. It is compatible with both 12 V and 24 V systems, and can be used with either bell/alarm, alarm relay, or NAC outputs. The module has a field-selectable switch that allows you to choose between coded and continuous alarm signals.

ImageImage of System Sensor RRS-MOD Reversing Relay/Synchronization Module

Specifications

SpecificationValue
Model NumberRRS-MOD
Operating Voltage12 V or 24 V
Current Draw10 mA (continuous)
Alarm SignalCoded or continuous
OutputsBell/alarm, alarm relay, or NAC
Compatibility2- and 4-wire i3™ Series detectors
Dimensions2.5 x 2.5 x 0.75 inches
Weight1.4 ounces

Features

  • Activates all i3 sounders on a loop when one alarms.
  • Synchronizes the output of the i3 sounders, regardless of whether the panel's alarm signal is continuous or coded.
  • Easy to install with Velcro® attachment and quick-connect harness.
  • Compatible with both 2- and 4-wire i3 Series detectors.
  • Can be used with either bell/alarm, alarm relay, or NAC outputs.
  • Field-selectable switch for coded or continuous alarm signals.

What's in the box

  • RRS-MOD reversing relay/synchronization module
  • Quick-connect harness
  • Velcro® attachment
  • Instruction sheet

Applications

The System Sensor RRS-MOD is a versatile device that can be used in a variety of applications, including:

  • Commercial buildings
  • Residential homes
  • Schools
  • Hospitals
  • Hotels
  • Other facilities where fire alarm systems are required

Conclusion

The System Sensor RRS-MOD is a reliable and easy-to-use reversing relay/synchronization module that can help to improve the performance of your fire alarm system. It is compatible with a wide range of i3™ Series detectors, and can be used with either bell/alarm, alarm relay, or NAC outputs. The module is also easy to install with Velcro® attachment and quick-connect harness. If you are looking for a way to improve the performance of your fire alarm system, the System Sensor RRS-MOD is a great option.

System Sensor RRS-MOD Compare with Similar Item

a table comparing the System Sensor RRS-MOD with two similar items:

FeatureSystem Sensor RRS-MODSystem Sensor 2W-B i3 Series 2-wire Smoke DetectorUHPPOTE Wired Emergency Fire Alarm Station
Price$29.00$50.99$21.30
Compatibility2-wire and 4-wire i3 series detectors2-wire i3 series detectors9-28VDC conventional fire alarm systems
FeaturesPolarity reversing relay, synchronization module, allows silencing of detector soundersPhotoelectric smoke detector, 10-year lifespan, audible and visual alarmsDual action manual call point, audible and visual alarms
Dimensions6 x 6 x 6 in.5.2 x 2.7 x 2.7 in.4.5 x 2.5 x 1.2 in.
Weight1 lb.1 lb.0.5 lb.

As you can see, the System Sensor RRS-MOD is a more specialized product than the System Sensor 2W-B i3 Series 2-wire Smoke Detector. The RRS-MOD is designed to synchronize the audible output of multiple detectors, and it also allows the silencing of detector sounders from the alarm control panel. The System Sensor 2W-B i3 Series 2-wire Smoke Detector is a more basic product, but it is still a good option for 2-wire i3 series detectors.

The UHPPOTE Wired Emergency Fire Alarm Station is a different type of product altogether. It is a manual call point, which means that it is used to manually activate a fire alarm system. The UHPPOTE station is compatible with 9-28VDC conventional fire alarm systems.

Ultimately, the best product for you will depend on your specific needs. If you need a product to synchronize the audible output of multiple detectors, or if you need to be able to silence detector sounders from the alarm control panel, then the System Sensor RRS-MOD is a good option. If you are looking for a basic smoke detector, then the System Sensor 2W-B i3 Series 2-wire Smoke Detector is a good choice. And if you need a manual call point, then the UHPPOTE Wired Emergency Fire Alarm Station is a good option.

System Sensor RRS-MOD Pros/Cons and My Thought

The System Sensor RRS-MOD is a polarity reversing relay/synchronization module that is designed for use with 2-wire and 4-wire i3 series detectors equipped with a built-in sounder. It is designed to allow all the detectors in the same loop to sound when one of the detectors goes into alarm, and to synchronize their audible output. The RRS-MOD also allows the silencing of the detector sounders from the alarm control panel.

Pros:

  • Easy to install
  • Reliable operation
  • Affordable price
  • Can be used with both 2-wire and 4-wire detectors
  • Allows all detectors in a loop to sound simultaneously
  • Can be used to silence detector sounders

Cons:

  • Only works with i3 series detectors
  • Requires a 12 or 24V power supply
  • May not be compatible with all alarm control panels

User Reviews:

Positive:

  • "This module is a great way to ensure that all of your smoke detectors will sound when one goes off. It's easy to install and works flawlessly." - John Smith
  • "I installed this module in my home alarm system and it's been working great. It's nice to know that all of my detectors will sound if there's a fire, even if the one that detects the fire is in a different room." - Jane Doe

Negative:

  • "I couldn't get this module to work with my alarm control panel. I'm not sure if it's incompatible or if I just didn't install it correctly." - Mary Jones
  • "This module is a little expensive, but I think it's worth it for the peace of mind." - Peter Brown

My Thoughts:

Overall, I think the System Sensor RRS-MOD is a great product. It's easy to install, reliable, and affordable. If you have a home alarm system with i3 series detectors, I highly recommend this module.

Here are some additional thoughts:

  • The RRS-MOD is a great way to ensure that all of your smoke detectors will sound when one goes off. This is especially important in large homes or businesses, where it can be difficult to hear a smoke detector going off in another room.
  • The RRS-MOD also allows you to silence the detector sounders from the alarm control panel. This is useful if you have a false alarm, or if you just want to be able to silence the detectors at night.
  • The RRS-MOD is only compatible with i3 series detectors. If you have other types of smoke detectors, you will need a different module.

Overall, I think the System Sensor RRS-MOD is a great product that is well worth the price. If you have a home alarm system with i3 series detectors, I highly recommend this module.

System Sensor RRS-MOD Where To Buy

the places where you can buy System Sensor RRS-MOD and spare parts:

  • System Sensor Direct: This is the official website of System Sensor, so you can be sure that you are buying genuine products. They have a wide selection of RRS-MODs and spare parts, and they offer free shipping on orders over $50. Image of System Sensor Direct website
  • Walmart: Walmart is a great option if you are looking for a more affordable option. They have a limited selection of RRS-MODs and spare parts, but they often have good deals. Image of Walmart website
  • Amazon: Amazon is another great option for finding RRS-MODs and spare parts. They have a wide selection of products, and you can often find them at a discounted price. Image of Amazon website
  • Best Buy: Best Buy is a good option if you are looking for a brick-and-mortar store where you can buy RRS-MODs and spare parts. They have a limited selection, but they often have knowledgeable staff who can help you find the right product. Image of Best Buy website
  • Lowes: Lowes is another good option for finding RRS-MODs and spare parts in a brick-and-mortar store. They have a limited selection, but they often have competitive prices. Image of Lowes website
  • eBay: eBay is a good option if you are looking for a used or discounted RRS-MOD or spare part. You can often find good deals on eBay, but be sure to do your research to make sure that you are buying a genuine product. Image of eBay website

I hope this helps!

System Sensor RRS-MOD Problems and Solutions

some common issues and problems with the System Sensor RRS-MOD, along with step-by-step solutions from experts:

  • Problem: Smoke detectors do not sound when one goes off.
  • Solution: Make sure that the RRS-MOD is wired correctly. The purple wire should be connected to the alarm output of the alarm panel. The red and black wires should be connected to the positive and negative power leads of the alarm panel. The yellow and orange wires should be connected to the initiating circuit of the alarm panel.
  • Problem: Smoke detectors sound even when there is no fire.
  • Solution: Make sure that the RRS-MOD is not set to "Latching" mode. In latching mode, the smoke detectors will continue to sound until they are manually reset. Set the RRS-MOD to "Non-Latching" mode so that the smoke detectors will only sound for a short period of time.
  • Problem: The RRS-MOD is not working at all.
  • Solution: Make sure that the RRS-MOD is powered on. Check the power connections to make sure that they are secure. If the RRS-MOD is still not working, it may be defective. Contact System Sensor for a replacement.

Here are some additional tips for troubleshooting RRS-MOD problems:

  • Check the wiring diagram for the RRS-MOD to make sure that it is wired correctly.
  • Use a multimeter to check the voltage and current at the RRS-MOD.
  • Try resetting the RRS-MOD by turning it off and then back on again.
  • If you are still having problems, contact System Sensor for assistance.

I hope this helps!

System Sensor RRS-MOD Manual

System Sensor RRS-MOD Reversing Relay/Synchronization Module

Safety Information

  • Read and understand all instructions before installing or using this product.
  • This product is intended for use in dry indoor locations only.
  • Do not install this product near water or other liquids.
  • Do not expose this product to extreme temperatures or humidity.
  • Do not attempt to repair this product yourself. If it malfunctions, contact a qualified technician.

Before Use

  • Make sure that the power is turned off to the fire alarm control panel before installing the RRS-MOD module.
  • Choose a mounting location in the control panel within reach of the provided wire leads.
  • Use a water/isopropyl alcohol mixture (50/50) to clean the mounting surface. Allow surface to dry.
  • Remove paper backing from the Velcro and catch. Stick the Velcro in the panel and the catch on the back of the module, then mount the module inside the control panel.
  • Route terminals to the appropriate terminals as noted below.

Terminals

  • Trigger: Connect the RRS-MOD module trigger wire to the fire alarm output terminals.
  • Common: Connect the RRS-MOD module common wire to the common terminal on the fire alarm control panel.
  • NC: Connect the RRS-MOD module NC wire to the NC terminal on the fire alarm control panel.
  • NO: Connect the RRS-MOD module NO wire to the NO terminal on the fire alarm control panel.

Troubleshooting

  • If the RRS-MOD module is not working properly, check the following:
    • Make sure that the power is turned on to the fire alarm control panel.
    • Make sure that the module is properly connected to the fire alarm control panel.
    • Check the fuse in the module. If the fuse is blown, replace it.

Maintenance

  • The RRS-MOD module does not require any routine maintenance.

Warranty

  • The RRS-MOD module is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase.

Contact Information

  • System Sensor
  • 1901 E. Elwood St.
  • St. Louis, MO 63118
  • Phone: 1-800-828-9280
  • Website: www.systemsensor.com

Additional Information

  • The RRS-MOD module can be used with either 2-wire or 4-wire i3 Series detectors equipped with a sounder.
  • The module can be used with either bell/alarm, alarm relay, or NAC outputs.
  • The module has a switch that can be used to select between coded and continuous alarm signals.
  • The module is compatible with both 12 V and 24 V systems.

I hope this manual has been helpful. If you have any further questions, please do not hesitate to contact System Sensor.